Resultados 1 - 20 de 1.860
Filtrar
1.
J Neurodev Disord ; 16(1): 6, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38429713

RESUMO

BACKGROUND: Angelman syndrome (AS) is a rare neurodevelopmental disorder characterized by severe intellectual disability, little to no expressive speech, visual and motor problems, emotional/behavioral challenges, and a tendency towards hyperphagia and weight gain. The characteristics of AS make it difficult to measure these children's functioning with standard clinical tests. Feasible outcome measures are needed to measure current functioning and change over time, in clinical practice and clinical trials. AIM: Our first aim is to assess the feasibility of several functional tests. We target domains of neurocognitive functioning and physical growth using the following measurement methods: eye-tracking, functional Near-Infrared Spectroscopy (fNIRS), indirect calorimetry, bio-impedance analysis (BIA), and BOD POD (air-displacement plethysmography). Our second aim is to explore the results of the above measures, in order to better understand the AS phenotype. METHODS: The study sample consisted of 28 children with AS aged 2-18 years. We defined an outcome measure as feasible when (1) at least 70% of participants successfully finished the measurement and (2) at least 60% of those participants had acceptable data quality. Adaptations to the test procedure and reasons for early termination were noted. Parents rated acceptability and importance and were invited to make recommendations to increase feasibility. The results of the measures were explored. RESULTS: Outcome measures obtained with eye-tracking and BOD POD met the definition of feasibility, while fNIRS, indirect calorimetry, and BIA did not. The most important reasons for early termination of measurements were showing signs of protest, inability to sit still and poor/no calibration (eye-tracking specific). Post-calibration was often applied to obtain valid eye-tracking results. Parents rated the BOD POD als most acceptable and fNIRS as least acceptable for their child. All outcome measures were rated to be important. Exploratory results indicated longer reaction times to high salient visual stimuli (eye-tracking) as well as high body fat percentage (BOD POD). CONCLUSIONS: Eye-tracking and BOD POD are feasible measurement methods for children with AS. Eye-tracking was successfully used to assess visual orienting functions in the current study and (with some practical adaptations) can potentially be used to assess other outcomes as well. BOD POD was successfully used to examine body composition. TRIAL REGISTRATION: Registered d.d. 23-04-2020 under number 'NL8550' in the Dutch Trial Register: https://onderzoekmetmensen.nl/en/trial/23075.


Assuntos
Síndrome de Angelman , Criança , Humanos , Síndrome de Angelman/complicações , Síndrome de Angelman/diagnóstico , Reprodutibilidade dos Testes , Composição Corporal , Pletismografia/métodos , Impedância Elétrica
2.
Pediatr Allergy Immunol Pulmonol ; 37(1): 7-12, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38484265

RESUMO

Background: Structured light plethysmography (SLP) is a novel light-based method that captures chest wall movements to evaluate tidal breathing. Methods: Thirty-two children who underwent lung surgery were enrolled. Their clinical history was collected along with spirometry and SLP. Results: Median age of surgery was 9 months (interquartile range 4-30). Most frequent diagnosis was congenital pulmonary airway malformation (14/32), then pulmonary sequestration (9/32), tumor (5/32), and bronchogenic cyst (4/32). The most frequent surgical approach was lobectomy (59%), segmentectomy (38%), and complete resection (3%). More than 80% had surgery when younger than 3 years of age. Eight patients had short-term complications (pleural effusion was the most frequent), while long-term effects were reported in 15 patients (19% recurrent cough, 13% thoracic deformities, 13% airway infections, 9% wheezing, 6% reduced exercise tolerance, and 3% columnar deformities). Spirometry was normal in 9/22 patients. Nine patients had a restrictive pattern, while 4 showed a mild bronco-reactivity. Ten patients did not perform spirometry because of young age. SLP revealed the presence of obstructive pattern in 10% of patients (IE50 > 1.88) and showed a significant difference between the two hemithorax in 29% of patients. Discussion: SLP may be a new method to evaluate lung function, without collaboration and radiation exposure, in children who underwent lung resection, also in preschool age.


Assuntos
Pletismografia , Procedimentos Cirúrgicos Pulmonares , Criança , Pré-Escolar , Humanos , Lactente , Pletismografia/métodos , Respiração , Espirometria/métodos , Pulmão/cirurgia
3.
Paediatr Anaesth ; 34(6): 559-567, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38348932

RESUMO

BACKGROUND: Intraoperative fluid therapy maintains normovolemia, normal tissue perfusion, normal metabolic function, normal electrolytes, and acid-base status. Plethysmographic variability index has been shown to predict fluid responsiveness but its role in guiding intraoperative fluid therapy is still elusive. AIMS: The aim of the present study was to compare intraoperative goal-directed fluid therapy based on plethysmographic variability index with liberal fluid therapy in term neonates undergoing abdominal surgeries. METHODS: A prospective randomized controlled study was conducted in a tertiary care centre, over a period of 18 months. A total of 30 neonates completed the study out of 132 neonates screened. Neonates with tracheoesophageal fistula, congenital diaphragmatic hernia, congenital heart disease, respiratory disorders, creatinine clearance <90 mL/min and who were hemodynamically unstable were excluded. Neonates were randomized to goal-directed fluid therapy group where the plethysmographic variability index was targeted at <18 or liberal fluid therapy group. Primary outcome was comparison of total amount of fluid infused intraoperatively in both the groups. Secondary outcomes included intraoperative and postoperative arterial blood gas parameters, biochemical parameters, use of vasopressors, number of fluid boluses, complications and duration of hospital stay. RESULTS: There was no significant difference in total intraoperative fluid infused [90 (84-117.5 mL) in goal-directed fluid therapy and 105 (85.5-144.5 mL) in liberal fluid therapy group (p = .406)], median difference (95% CI) -15 (-49.1 to 19.1). There was a decrease in serum lactate levels in both groups from preoperative to postoperative 24 h. The amount of fluid infused before dopamine administration was significantly higher in liberal fluid therapy group (58 [50.25-65 mL]) compared to goal-directed fluid therapy group (36 [22-44 mL], p = .008), median difference (95% CI) -22 (-46 to 2). In postoperative period, the total amount of fluid intake over 24 h was comparable in two groups (222 [204-253 mL] in goal-directed fluid therapy group and 224 [179.5-289.5 mL] in liberal fluid therapy group, p = .917) median difference (95% CI) cutoff -2 (-65.3 to 61.2). CONCLUSION: Intraoperative plethysmographic variability index-guided goal-directed fluid therapy was comparable to liberal fluid therapy in terms of total volume of fluid infused in neonates during perioperative period. More randomized controlled trials with higher sample size are required. TRIAL REGISTRATION: Central Trial Registry of India (CTRI/2020/02/023561).


Assuntos
Abdome , Hidratação , Pletismografia , Humanos , Hidratação/métodos , Recém-Nascido , Estudos Prospectivos , Masculino , Feminino , Pletismografia/métodos , Abdome/cirurgia , Gasometria/métodos , Cuidados Intraoperatórios/métodos , Resultado do Tratamento
4.
Clin Transl Sci ; 17(2): e13735, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38344891

RESUMO

Buloxibutid (also known as C21) is a potent and selective angiotensin II type 2 receptor (AT2R) agonist, in development for oral treatment of fibrotic lung disease. This phase I, open-label, pharmacodynamic study investigated vascular effects of buloxibutid in five healthy male volunteers. Subjects were administered intra-arterial infusions of buloxibutid for 5 min in ascending doses of 3, 10, 30, 100, and 200 µg/min, infused sequentially in the forearm. Infusions of sodium nitroprusside (SNP) solution in doses of 0.8-3.2 µg/min were administered as a positive control. Forearm blood flow (FBF) was measured by venous occlusion plethysmography. Safety and tolerability of intra-arterial administrations of buloxibutid were evaluated. Following infusion of buloxibutid in doses of 3-200 µg/min, the range of increase in FBF was 27.8%, 17.2%, 37.0%, 28.5%, and 60.5%, compared to the respective baseline. The largest increase was observed in the highest dose group. Infusions of SNP as a positive control, increased FBF 230-320% compared to baseline. Three adverse events (AEs) of mild intensity, not related to buloxibutid or SNP, were reported for two subjects. Two of these AEs were related to study procedures. There were no clinically relevant changes in arterial blood pressure during the study period. Intra-arterial infusion of buloxibutid in low, ascending doses increased FBF, indicating that buloxibutid may be effective in conditions associated with endothelial dysfunction. Venous occlusion plethysmography was found to be a useful method to explore pharmacodynamic vascular effects of novel AT2R agonists, while avoiding systemic adverse effects.


Assuntos
Pletismografia , Receptor Tipo 2 de Angiotensina , Humanos , Masculino , Nitroprussiato/efeitos adversos , Pletismografia/métodos , Antebraço/irrigação sanguínea , Fluxo Sanguíneo Regional , Vasodilatação
5.
Artigo em Inglês | MEDLINE | ID: mdl-38265049

RESUMO

AIM: To determine the validity of bioelectrical impedance analysis (BIA) in quantifying fat-free mass (FFM) compared to air-displacement plethysmography (ADP) in patients with a motor neurone disease (MND). METHODS: FFM of 140 patients diagnosed with MND was determined by ADP using the BodPod (i.e. the gold standard), and by BIA using the whole-body Bodystat. FFM values were translated to predicted resting energy expenditure (REE); the actual REE was measured using indirect calorimetry, resulting in a metabolic index. Validity of the BIA compared to the ADP was assessed using Bland-Altman analysis and Pearson's r. To assess the clinical relevance of differences, we evaluated changes in metabolic index and in individualized protein demand. RESULTS: Despite the high correlation between ADP and BIA (r = 0.93), averaged across patients, the assessed mean fat-free mass was 51.7 kg (± 0.9) using ADP and 54.2 kg (± 1.0) using BIA. Hence, BIA overestimated fat-free mass by 2.5 kg (95% CI 1.8-3.2, p < 0.001). Clinically, an increased metabolic index would be more often underdiagnosed in patients with MND using BIA (31.4% according to BIA versus 44.2% according to ADP, p = 0.048). A clinically relevant overestimation of ≥ 15 g in protein demand was observed for 4 (2.9%) patients using BIA. CONCLUSIONS: BIA systematically overestimates FFM in patients with MND. Although the differences are limited with ADP, underscoring the utility of BIA for research, overestimation of fat-free mass may have consequences for clinical decision-making, especially when interest lies in determining the metabolic index.


Assuntos
Esclerose Amiotrófica Lateral , Doença dos Neurônios Motores , Humanos , Composição Corporal , Estudos Transversais , Pletismografia/métodos , Impedância Elétrica , Reprodutibilidade dos Testes , Doença dos Neurônios Motores/diagnóstico
6.
Sensors (Basel) ; 23(24)2023 Dec 10.
Artigo em Inglês | MEDLINE | ID: mdl-38139582

RESUMO

Respiratory rate monitoring is fundamental in clinical settings, and the accuracy of measurement methods is critical. This study aimed to develop and validate methods for assessing respiratory rate and the duration leof respiratory cycle phases in different body positions using optoelectronic plethysmography (OEP) based on a motion capture video system. Two analysis methods, the summation method and the triangle method were developed. The study focused on determining the optimal number of markers while achieving accuracy in respiratory parameter measurements. The results showed that most analysis methods showed a difference of ≤0.5 breaths per minute, with R2 ≥ 0.94 (p < 0.001) compared to spirometry. The best OEP methods for respiratory rate were the abdominal triangles and the sum of abdominal markers in all body positions. The study explored inspiratory and expiratory durations. The research found that 5-9 markers were sufficient to accurately determine respiratory time components in all body positions, reducing the marker requirements compared to previous studies. This interchangeability of OEP methods with standard spirometry demonstrates the potential of non-invasive methods for the simultaneous assessment of body segment movements, center of pressure dynamics, and respiratory movements. Future research is required to improve the clinical applicability of these methods.


Assuntos
Captura de Movimento , Taxa Respiratória , Respiração , Pletismografia/métodos , Espirometria
7.
Sensors (Basel) ; 23(15)2023 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-37571742

RESUMO

The identification of respiratory patterns based on the movement of the chest wall can assist in monitoring an individual's health status, particularly those with neuromuscular disorders, such as hemiplegia and Duchenne muscular dystrophy. Thoraco-abdominal asynchrony (TAA) refers to the lack of coordination between the rib cage and abdominal movements, characterized by a time delay in their expansion. Motion capture systems, like optoelectronic plethysmography (OEP), are commonly employed to assess these asynchronous movements. However, alternative technologies able to capture chest wall movements without physical contact, such as RGB digital cameras and time-of-flight digital cameras, can also be utilized due to their accessibility, affordability, and non-invasive nature. This study explores the possibility of using a single RGB digital camera to record the kinematics of the thoracic and abdominal regions by placing four non-reflective markers on the torso. In order to choose the positions of these markers, we previously investigated the movements of 89 chest wall landmarks using OEP. Laboratory tests and volunteer experiments were conducted to assess the viability of the proposed system in capturing the kinematics of the chest wall and estimating various time-related respiratory parameters (i.e., fR, Ti, Te, and Ttot) as well as TAA indexes. The results demonstrate a high level of agreement between the detected chest wall kinematics and the reference data. Furthermore, the system shows promising potential in estimating time-related respiratory parameters and identifying phase shifts indicative of TAA, thus suggesting its feasibility in detecting abnormal chest wall movements without physical contact with a single RGB camera.


Assuntos
Parede Torácica , Humanos , Estudos de Viabilidade , Fenômenos Biomecânicos , Mecânica Respiratória , Respiração , Pletismografia/métodos
8.
Nutrition ; 114: 112133, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37499562

RESUMO

OBJECTIVES: The aim of this study is to develop predictive body fat mass models, one for newborns and one for infants, using air displacement plethysmography as a reference method. METHODS: The study was carried out with 125 newborns (1-5 d of age) and 71 infants (≥3-6 mo). The stepwise method was used to estimate the final model from the predictors of sex, weight, length, triceps skinfold, waist circumference, mean arm circumference, and gestational age. The quality of the models was evaluated by the determination coefficient, variance inflation factor, and residual analysis. The paired t test and Bland-Altman plot were used to assess the agreement between observed and estimated values. RESULTS: The final model for newborns was - 0.76638 + 0.2512 * weight (kg) + 0.0620 * PCT (mm) + 0.0754 * gender (R² = 70%) and the final model for infants: -2.22748 + 0.4928 * weight (kg) + 0.0737 * TSF (mm) + 0.2647 * gender (R² = 84%). CONCLUSIONS: This work determined equations to estimate the BFM of term newborns and infants. The models can be used in clinical practice, especially in health units without access to technologies for measuring body composition, adding important information for nutritional monitoring.


Assuntos
Tecido Adiposo , Composição Corporal , Humanos , Recém-Nascido , Lactente , Idoso , Peso Corporal , Antropometria/métodos , Idade Gestacional , Pletismografia/métodos
9.
J Pediatr Gastroenterol Nutr ; 77(4): 553-557, 2023 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-37496142

RESUMO

BACKGROUND: The nutritional status of children with intestinal failure (IF) can be difficult to determine using body weight and currently available anthropometric techniques. Air displacement plethysmography (ADP) is a noninvasive measure of whole-body composition that measures body mass and volume, with a calculation of percent body fat (%BF) and fat-free mass (FFM) that may be useful during the provision of specialized nutrition. OBJECTIVES: To evaluate the validity and feasibility of measuring body composition in children with IF using ADP compared with deuterium dilution (DD), as well as secondarily with other measures of body composition, namely bioelectrical impedance analysis (BIA), dual-energy X-ray absorptiometry (DXA), and four-site skinfold anthropometry. METHODS: We conducted a prospective cohort study of 18 children recruited through the Center for Advanced Intestinal Rehabilitation at Boston Children's Hospital. Patients 2-17 years of age with IF dependent on parenteral nutrition (PN) for more than 90 days were included. Spearman rank correlation and Bland-Altman limits of agreement (LOA) analysis were used to compare ADP to 4 alternative measures of body composition. RESULTS: Eighteen children with IF, median age 7.1 [interquartile range (IQR) 5.4-9.3] years, 9 female (50%), and median residual bowel length 31 (IQR 22-85) cm were enrolled. Median PN energy intake was 46 (IQR 39-49) kcal/kg/day. Incomplete bladder emptying lead to invalid measures of DD in 4 subjects. Spearman correlation coefficients for %BF were low to moderate between ADP and DD ( r = 0.29), DXA ( r = 0.62), BIA ( r = 0.50), and skinfold ( r = 0.40). Correlations for FFM were high between ADP and these other measures (range 0.95-0.98). Comparing ADP with DD and skinfold measures, Bland-Altman analysis showed small mean bias (-1.9 and +1.5 kg) and acceptable 95% LOA ranges (10.7 and 22.9 kg), respectively, with larger bias (-10.7 and -7.7 kg) and LOA ranges (38.7 and 45.2 kg) compared to DXA and BIA. %BF by ADP and skinfold thickness were moderately correlated ( r = 0.43) with low bias (-0.2%) but very wide LOA (25.7%). CONCLUSIONS: Body composition via ADP is feasible and valid in children with IF as a measure of FFM but appears less suitable for the measurement of %BF. The technique holds promise as a noninvasive measure of body composition to assess the efficacy of nutritional, medical, and surgical interventions.


Assuntos
Insuficiência Intestinal , Humanos , Criança , Feminino , Pré-Escolar , Lactente , Estudos Prospectivos , Pletismografia/métodos , Impedância Elétrica , Composição Corporal , Tecido Adiposo , Absorciometria de Fóton/métodos , Reprodutibilidade dos Testes
10.
Front Public Health ; 11: 1164556, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37469700

RESUMO

Background: Accurate assessment of body composition (BC) is important to investigate the development of childhood obesity. A bioelectrical impedance analysis (BIA) device is portable and inexpensive compared with air displacement plethysmography (ADP) for the assessment of BC and is widely used in children. However, studies of the effectiveness of BIA are few and present different results, especially in pediatric populations. The aim of this study was to evaluate the agreement between BIA and ADP for estimating BC. Methods: The BC of 981 Chinese children (3-5 years) was measured using the BIA device (SeeHigher BAS-H, China) and ADP (BOD POD). Results: Our results showed that BIA underestimated fat mass (FM) and overestimated fat-free mass (FFM) in normal weight children (P < 0.05), but the opposite trend was shown in children with obesity (P < 0.05). The agreement between FM and FFM measured by the two methods was strong (CCC > 0.80). The linear regression equation of 5-year-old children was constructed. Conclusion: The SeeHigher BAS-H multi-frequency BIA device is a valid device to evaluate BC in Chinese preschool children compared with ADP (BOD POD), especially in 5-year-old children or children with obesity. Further research is needed to standardize the assessment of BC in children.


Assuntos
Obesidade Pediátrica , Pletismografia , Criança , Humanos , Pré-Escolar , Impedância Elétrica , Pletismografia/métodos , Composição Corporal , Modelos Lineares
11.
Clin Nutr ; 42(9): 1588-1594, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37478812

RESUMO

BACKGROUND & AIMS: Air-Displacement-Plethysmography (ADP) by BOD POD is widely used for body fat assessment in children. Although validated in healthy subjects, studies about use in pediatric patients are lacking. We evaluated user experience and usability of ADP measurements with the BOD POD system in healthy children and pediatric and young adult patients. METHODS: Using the experiences of seven cohort studies, which included healthy children and patients aged 2-22 years, we retrospectively evaluated the user experience with the User Experience Questionnaire (UEQ) (n = 13) and interviews (n = 7). Technical performance was studied using the quality control data collected by the ADP-system. RESULTS: From 2016 to 2022, 1606 measurements were scheduled. BOD POD was mostly rated 'user-friendly', with a generally neutral evaluation on all scales of the UEQ. However, questionable reliability and validity of the results were frequently (86%) reported. We found a high technical failure-rate of the device, predominantly in stability (17%) and accuracy of the measurement (12%), especially in the 'pediatric option' for children aged <6 years. Measurement failure-rate was 38%, mostly due to subject's fear or device failure, especially in young and lean children, and in children with physical and/or intellectual disabilities. CONCLUSION: We conclude that ADP by BOD POD in children and young adults is non-invasive and user-friendly. However, in specific pediatric populations, BOD POD has several limitations and high (technical) failure-rates, especially in young children with aberrant body composition. We recommend caution when interpreting body composition results of pediatric patients as assessed with BOD POD using the current default settings.


Assuntos
Composição Corporal , Pletismografia , Humanos , Adulto Jovem , Criança , Pré-Escolar , Reprodutibilidade dos Testes , Estudos Retrospectivos , Pletismografia/métodos , Tecido Adiposo
12.
Am J Clin Nutr ; 117(6): 1262-1269, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37270290

RESUMO

BACKGROUND: Body composition assessment in the first 2 y of life provides important insights into child nutrition and health. The application and interpretation of body composition data in infants and young children have been challenged by a lack of global reference data. OBJECTIVES: We aimed to develop body composition reference charts of infants aged 0-6 mo based on air displacement plethysmography (ADP) and those aged 3-24 mo based on total body water (TBW) by deuterium dilution (DD). METHODS: Body composition was assessed by ADP in infants aged 0-6 mo from Australia, India, and South Africa. TBW using DD was assessed for infants aged 3-24 mo from Brazil, Pakistan, South Africa, and Sri Lanka. Reference charts and centiles were constructed for body composition using the lambda-mu-sigma method. RESULTS: Sex-specific reference charts were produced for FM index (FMI), FFM index (FFMI), and percent FM (%FM) for infants aged 0-6 mo (n = 470 infants; 1899 observations) and 3-24 mo (n = 1026 infants; 3690 observations). When compared with other available references, there were observable differences but similar patterns in the trajectories of FMI, FFMI, and %FM. CONCLUSIONS: These reference charts will strengthen the interpretation and understanding of body composition in infants across the first 24 mo of life.


Assuntos
Composição Corporal , Pletismografia , Masculino , Criança , Feminino , Lactente , Humanos , Pré-Escolar , Índice de Massa Corporal , Pletismografia/métodos , Fenômenos Fisiológicos da Nutrição Infantil , Austrália , Tecido Adiposo/metabolismo
13.
Eur J Clin Nutr ; 77(7): 748-756, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37055482

RESUMO

BACKGROUND/OBJECTIVES: Fat-mass (FM) assessment since birth using valid methodologies is crucial since excessive adiposity represents a risk factor for adverse metabolic outcomes. AIM: To develop infant FM prediction equations using anthropometry and validate them against air-displacement plethysmography (ADP). SUBJECTS/METHODS: Clinical, anthropometric (weight, length, body-mass index -BMI-, circumferences, and skinfolds), and FM (ADP) data were collected from healthy-term infants at 1 (n = 133), 3 (n = 105), and 6 (n = 101) months enrolled in the OBESO perinatal cohort (Mexico City). FM prediction models were developed in 3 steps: 1) Variable Selection (LASSO regression), 2) Model behavior evaluation (12-fold cross-validation, using Theil-Sen regressions), and 3) Final model evaluation (Bland-Altman plots, Deming regression). RESULTS: Relevant variables in the FM prediction models included BMI, circumferences (waist, thigh, and calf), and skinfolds (waist, triceps, subscapular, thigh, and calf). The R2 of each model was 1 M: 0.54, 3 M: 0.69, 6 M: 0.63. Predicted FM showed high correlation values (r ≥ 0.73, p < 0.001) with FM measured with ADP. There were no significant differences between predicted vs measured FM (1 M: 0.62 vs 0.6; 3 M: 1.2 vs 1.35; 6 M: 1.65 vs 1.76 kg; p > 0.05). Bias were: 1 M -0.021 (95%CI: -0.050 to 0.008), 3 M: 0.014 (95%CI: 0.090-0.195), 6 M: 0.108 (95%CI: 0.046-0.169). CONCLUSION: Anthropometry-based prediction equations are inexpensive and represent a more accessible method to estimate body composition. The proposed equations are useful for evaluating FM in Mexican infants.


Assuntos
Composição Corporal , Pletismografia , Feminino , Humanos , Lactente , Gravidez , Antropometria/métodos , Índice de Massa Corporal , México , Pletismografia/métodos , Reprodutibilidade dos Testes
14.
J Paediatr Child Health ; 59(3): 470-479, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36661380

RESUMO

AIM: This study aimed to compare body composition (BC) measurements obtained by three widely used BC measuring methods, air displacement plethysmography (ADP), bioelectrical impedance analysis (BIA) and dual-energy X-ray absorptiometry (DXA), in Chinese children and adolescents by sex and different BMI categories. METHODS: We used three BC measuring methods to evaluate healthy Chinese children and adolescents aged 5-17 years with BMI categories ranging from underweight to obese. Fat mass (FM, kg), fat mass percentage (FMP, %), fat-free mass (FFM, kg) and appendicular skeletal muscle mass (ASM, kg) were measured by DXA, BIA and ADP on the same day within 1 h. RESULTS: A total of 172 Chinese children and adolescents were included in this study. The agreements for FM, FFM and ASM estimated by the three methods were excellent or good at the population level (intraclass correlation coefficient > 0.850, P < 0.05). However, ADP or BIA estimated lower body fat content and higher FFM than DXA (P < 0.001 for all). Moreover, the precise estimates significantly varied across BMI categories. In addition, the limit of agreements was wide, and the differences might not be clinically acceptable at the individual level. CONCLUSIONS: Body fat and FFM obtained by the three commonly used methods were highly correlated, but systematically different and influenced by BMI. This study provided a basis for mutual reference of measurements between three widely used methods.


Assuntos
Composição Corporal , População do Leste Asiático , Humanos , Adolescente , Criança , Absorciometria de Fóton/métodos , Impedância Elétrica , Composição Corporal/fisiologia , Pletismografia/métodos , Reprodutibilidade dos Testes , Índice de Massa Corporal
15.
Pediatr Res ; 93(5): 1120-1140, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-35995939

RESUMO

BACKGROUND: There are several methods to measure body composition in preterm infants. Yet, there is no agreement on which method should be preferred. METHODS: PubMed, Embase.com, Wiley/Cochrane Library, and Google Scholar were searched for studies that reported on the predictive value or validity of body composition measurements in preterms, up to 6 months corrected age. RESULTS: Nineteen out of 1884 identified studies were included. Predictive equations based on weight and length indices, body area circumferences, skinfold thickness, bioelectrical impedance, and ultrasound did not show agreement with body composition measured with air displacement plethysmography (ADP), dual-energy x-ray absorptiometry (DXA), magnetic resonance imaging (MRI), or isotope dilution. ADP agreed well with fat mass density measured by isotope dilution (bias -0.002 g/ml, limits of agreement ±0.012 g/ml, n = 14). Fat mass percentage measured with ADP did not agree well with fat mass percentage measured by isotope dilution (limits of agreement up to ±5.8%) and the bias between measurements was up to 2.2%. DXA, MRI, and isotope dilution were not compared to another reference method in preterms. CONCLUSIONS: DXA, ADP, and isotope dilution methods are considered trustworthy validated techniques. Nevertheless, this review showed that these methods may not yield comparable results. IMPACT: Based on validation studies that were conducted in a limited number of study subjects, weight and length indices, body area circumferences, skinfold thickness, bioelectrical impedance, and ultrasound seem to be a poor representation of body composition in preterm infants. DXA, ADP, and isotope dilution methods are considered trustworthy and validated techniques. Nevertheless, these methods may not yield comparable results.


Assuntos
Tecido Adiposo , Recém-Nascido Prematuro , Humanos , Recém-Nascido , Tecido Adiposo/metabolismo , Composição Corporal , Dobras Cutâneas , Absorciometria de Fóton/métodos , Impedância Elétrica , Pletismografia/métodos , Reprodutibilidade dos Testes
16.
Br J Nutr ; 130(6): 1098-1104, 2023 09 28.
Artigo em Inglês | MEDLINE | ID: mdl-36562205

RESUMO

Air displacement plethysmography (ADP) has been considered as the 'standard' method to determine body fat in children due to superior validity and reliability compared with bioelectrical impedance analysis (BIA). However, ADP and BIA are often used interchangeably despite few studies comparing measures of percentage body fat by ADP (%FMADP) with BIA (%FMBIA) in children with and without obesity. The objective of this study was to measure concurrent validity and reliability of %FMADP and %FMBIA in 6-to-12-year-old boys with and without obesity. Seventy-one boys (twenty-five with obesity) underwent body composition assessment. Ten boys participated in intra-day reliability analysis. %FMADP was estimated by Bodpod using sex- and age-specific equations of body density. %FMBIA was estimated by a multi-frequency, hand-to-foot device using child-specific equations based on impedance. Validity was assessed by t tests, correlation coefficients and limits of agreement (LoA); and reliability by technical error of measurement (TEM) and intraclass correlation coefficients (ICC). Compared with %FMADP, %FMBIA was significantly underestimated in the cohort (-3·4 ± 5·6 %; effect size = 0·42) and in both boys with obesity (-5·2 ± 5·5 %; ES = 0·90) and without obesity (-2·4 ± 5·5 %; ES = 0·52). A strong, significant positive correlation was found between %FMADP and %FMBIA (r = 0·80). Across the cohort, LoA were 22·3 %, and no proportional bias was detected. For reliability, TEM were 0·65 % and 0·55 %, and ICC were 0·93 and 0·95 for %FMBIA and %FMADP, respectively. Whilst both %FMADP and %FMBIA are highly reliable methods, considerable differences indicated that the devices cannot be used interchangeably in boys age 6-to-12 years.


Assuntos
Tecido Adiposo , Pletismografia , Masculino , Humanos , Criança , Impedância Elétrica , Reprodutibilidade dos Testes , Pletismografia/métodos , Composição Corporal , Obesidade/diagnóstico , Absorciometria de Fóton
17.
Adv Physiol Educ ; 47(1): 97-116, 2023 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-36476117

RESUMO

Vascular diseases of the legs are highly prevalent and constitute an important part of medical curricula. The understanding of these diseases relies on strongly interwoven aspects of vascular physiology and vascular medicine. We aimed to connect these within a horizontally integrated laboratory class on vascular physiology of the leg that was designed in cooperation between the departments of physiology and vascular surgery. Conceptually, we applied examination techniques of vascular medicine to visualize physiological parameters that are altered by the most frequent diseases. This facilitates integrative discussions on malfunctions, trains diagnostic skills, and bridges to vascular medicine. In four experiments, we use oscillometry and impedance venous occlusion plethysmography to address key aspects of the arterial and venous system of the legs: 1) arterial pulse wave, 2) arterial systolic blood pressure, 3) venous capacitance and venous outflow, and 4) reactive hyperemia. After the experiments, physiological vascular function, the associated diseases, their impact on the recorded parameters, and diagnostic options are discussed. To allow reproduction, we describe the course structure and the experimental setup in detail. We present the experimental data of a cohort of medical students and document learning success and student satisfaction. All experiments were feasible and provided robust data on physiologically and clinically relevant vascular functions. The activity was perceived positively by the students and led to a substantial improvement of knowledge. With this work, we offer a template for reproduction or variation of a proven concept of horizontally integrated teaching of vascular physiology of the leg.NEW & NOTEWORTHY This article presents an integrative laboratory class on vascular physiology bridging to vascular medicine. The four experiments rely on oscillometry and venous occlusion plethysmography. We describe in detail this new class regarding structure, experimental setup, and experimental procedure, and we give insight into the applied materials. Moreover, we present the experimental data of 74 students and a quantitative evaluation of the students' learning success and acceptance.


Assuntos
Cardiologia , Fisiologia , Humanos , Pletismografia/métodos , Veias/fisiologia , Pressão Sanguínea
18.
Sensors (Basel) ; 22(24)2022 Dec 10.
Artigo em Inglês | MEDLINE | ID: mdl-36560048

RESUMO

Depth-based plethysmography (DPG) for the measurement of respiratory parameters is a mobile and cost-effective alternative to spirometry and body plethysmography. In addition, natural breathing can be measured without a mouthpiece, and breathing mechanics can be visualized. This paper aims at showing further improvements for DPG by analyzing recent developments regarding the individual components of a DPG measurement. Starting from the advantages and application scenarios, measurement scenarios and recording devices, selection algorithms and location of a region of interest (ROI) on the upper body, signal processing steps, models for error minimization with a reference measurement device, and final evaluation procedures are presented and discussed. It is shown that ROI selection has an impact on signal quality. Adaptive methods and dynamic referencing of body points to select the ROI can allow more accurate placement and thus lead to better signal quality. Multiple different ROIs can be used to assess breathing mechanics and distinguish patient groups. Signal acquisition can be performed quickly using arithmetic calculations and is not inferior to complex 3D reconstruction algorithms. It is shown that linear models provide a good approximation of the signal. However, further dependencies, such as personal characteristics, may lead to non-linear models in the future. Finally, it is pointed out to focus developments with respect to single-camera systems and to focus on independence from an individual calibration in the evaluation.


Assuntos
Pletismografia , Mecânica Respiratória , Humanos , Pletismografia/métodos , Espirometria , Taxa Respiratória , Modelos Lineares , Respiração
19.
Sci Rep ; 12(1): 19255, 2022 11 10.
Artigo em Inglês | MEDLINE | ID: mdl-36357452

RESUMO

Measuring breathing rates without a mouthpiece is of interest in clinical settings. Electrocardiogram devices and, more recently, optoelectronic plethysmography (OEP) methods can estimate breathing rates with only a few electrodes or motion-capture markers placed on the patient. This study estimated and compared the accuracy and reliability of three non-invasive devices: an OEP system with 12 markers, an electrocardiogram device and the conventional spirometer. Using the three devices simultaneously, we recorded 72 six-minute epochs on supine subjects. Our results show that the OEP system has a very low limit of agreement and a bias lower than 0.4% compared with the spirometer, indicating that these devices can be used interchangeably. We observed comparable results for electrocardiogram devices. The OEP system facilitates breathing rate measurements and offers a more complete chest-lung volume analysis that can be easily associated with heart rate analysis without any synchronisation process, for useful features for clinical applications and intensive care.


Assuntos
Pletismografia , Respiração , Humanos , Frequência Cardíaca , Reprodutibilidade dos Testes , Pletismografia/métodos , Medidas de Volume Pulmonar/métodos , Espirometria
20.
Annu Int Conf IEEE Eng Med Biol Soc ; 2022: 3396-3400, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-36086653

RESUMO

The study of plethysmography time series is crucial to better understand the breathing behavior of mice, in particular the influence of neurotoxins on the respiratory system. Current approaches rely on a few respiratory descriptors computed on individual breathing cycles that fail to account for the variety of breathing habits and their evolution with time. In this paper we introduce a new procedure for the automatic analysis of plethysmography signals. Our method relies on a new and robust segmentation of respiratory cycles and a DTW-based clustering algorithm to extract the most typical respiratory cycles (called reference sequences). We can then create a symbolic representation of any new recording by matching respiratory cycles to their closest reference sequence. This new representation is a visual and quantitative tool to assess the breathing behavior of mice and its evolution with time. Our method is applied to plethysmography signals collected on mice with two different genotypes and exposed to a neurotoxin. Clinical relevance This article proposes a novel approach to study plethysmography data. Our algorithm is able to accurately extract clinically meaningful respiratory cycles and the associated ventilation patterns descriptors such as tidal volume and inhalation/exhalation duration. In addition, thanks to the associated symbolic representation of signals, the temporal evolution of respiration is easily quantified. This opens a new research path to study the often slowly evolving and subtle influence of neurotoxins on the respiratory system.


Assuntos
Neurotoxinas , Pletismografia , Análise por Conglomerados , Pletismografia/métodos , Respiração , Volume de Ventilação Pulmonar
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...